Atlas / Chemistry / The Analysis Thread

Field · Emerged 1903 – 1990

Chromatography

How can a mixture of hundreds of similar substances be separated into its components, one after another, by making each one hesitate for a different length of time?

4 chapters7 min read6 turning points1 open problem

Branched from
Quantitative Analysis
Branched into
Not yet surveyed past here
Figures
Mikhail Tsvet, Archer Martin, Richard Synge, Raphael Consden, Alfred Gordon, Anthony James, Marcel Golay, Csaba Horváth, Jack Kirkland, James Jorgenson, Krynn Lukacs

In brief

Mikhail Tsvet poured a solution of leaf pigments through a column of chalk in 1906 and watched them separate into coloured bands, each pigment held back by a different amount. The principle generalises completely: give the components of a mixture a choice between a stationary phase that retains them and a mobile phase that carries them along, and anything that differs in that preference, however slightly, will emerge at a different time.

What made it the dominant technique in chemistry is that the resolving power can be bought. Each element of the column acts as a separate equilibration, so a long column performs the separation thousands of times over, and the separation between two peaks improves as the square root of the number of such stages. A 30-metre capillary column with 150,000 stages separates components whose affinities differ by one per cent — which is how a petroleum fraction with hundreds of hydrocarbons, or the amino acids from a hydrolysed protein, became analysable at all. Archer Martin and Richard Synge's partition theory of 1941 earned a Nobel Prize, and their paper noted in passing that a gas would work as the mobile phase, which took eleven years for anyone to try.

Key ideas

Two phases, one choiceEnters 1903 – 1906

A stationary phase that retains and a mobile phase that carries. Every component partitions between them continuously, so its speed down the column depends on the fraction of time it spends in each, and components that differ at all in that fraction separate.

Partition and the plateEnters 1941 – 1952

Treating the column as a series of stages, each reaching equilibrium between the phases. The number of stages — theoretical plates — measures the column's power, and the separation between peaks grows as its square root.

Retention timeEnters 1952 – 1958

When a component emerges. Under fixed conditions it identifies the substance, and the area under its peak measures how much there was — so one run gives both qualitative and quantitative answers.

Gradient elutionEnters 1967 – 1980

Changing the mobile phase during the run, so that strongly retained components are pushed off without the weakly retained ones emerging in a single rush. It extends the range of a single analysis by orders of magnitude.

Peak capacityEnters 1981 – 1998

How many components a run can resolve, which is set by how many peak widths fit into the available time. It is a few hundred for a good single separation and a few thousand for two dimensions, against samples containing far more.

Electro-driven separationEnters 1981 – 1998

Using an electric field rather than pressure to move the sample, so the flow has no parabolic profile and the peaks stay sharp. In a narrow capillary it gives hundreds of thousands of plates and needs nanolitres of sample.

Chapter I

Hesitation as a Separation

Mikhail Tsvet was trying to settle whether chlorophyll is one substance or several. He poured an extract of leaves, dissolved in petroleum ether, through a glass tube packed with powdered chalk, and the extract separated as it descended into distinct bands of green and yellow. Each pigment stuck to the chalk to a different degree, so each travelled at its own speed. He named the method after the colours — chromatography — and published in botanical journals, in German and Russian, in 1906.

Photograph of Mikhail Tsvet with a moustache and a short beard.
Mikhail Tsvet, who separated leaf pigments into coloured bands down a column of chalk and named the method chromatography, colour-writing.Unknown photographer · Public domain · Source

Chemists did not notice for thirty years, which is one of the longer delays in the atlas. Part of the reason is that his conclusion was unpopular: the great Richard Willstätter held that chlorophyll was a single compound, and Tsvet's bands said otherwise. Part is that the technique looked like a botanist's trick rather than a general method.

It is in fact entirely general, because the only requirement is that components differ in how much they prefer one phase to another. Adsorption on a solid will do it; so will dissolving in a liquid held on a support, which is what Archer Martin and Richard Synge used in 1941 when they needed to separate the amino acids from wool. Their contribution was as much theoretical as practical, and it is the reason the technique became quantitative.

Chapter II

Why There Is an Optimum Flow Rate

Plate theory counts the equilibrations and says nothing about what limits their number. Three processes broaden a band as it travels, and because they depend differently on how fast the mobile phase moves, there is a speed at which the column performs best — slower is worse as well as faster.

The analysis is Jan van Deemter's, and it states the plate height as a sum:

H=A+Bu+Cu,H = A + \frac{B}{u} + Cu,

where uu is the mobile-phase velocity.

The AA term is packing irregularity: molecules take different paths through a bed of particles, some shorter than others, so the band spreads by an amount independent of speed. It is reduced by packing uniformly with small particles and vanishes entirely in an open capillary, which is one reason capillary columns outperform packed ones.

The B/uB/u term is longitudinal diffusion: while the band is in the column it spreads by ordinary diffusion along the direction of travel, and the slower it moves the longer it has to do so. This term punishes going too slowly.

The CuCu term is resistance to mass transfer: a molecule must diffuse into and out of the stationary phase to be retained, and if the band moves fast there is not time for equilibrium, so the molecules at the front run ahead of those still in the stationary phase. This term punishes going too fast, and it is why a thick stationary phase broadens peaks.

Differentiating gives the optimum at u=B/Cu = \sqrt{B/C}, with minimum plate height H=A+2BCH = A + 2\sqrt{BC}. For a gas chromatographic capillary that optimum is around 20 to 40 cm/s, and the curve is shallow on the fast side — which is the practically important detail, since it means a separation can be run two or three times faster than optimal at modest cost in resolution, and cannot be improved by running slowly.

The equation also explains the last thirty years of column development as a campaign against each term in turn: smaller particles to reduce AA and CC, which costs pressure and produced the move to ultra-high-pressure instruments; thinner stationary films to reduce CC; and for a gas, hydrogen rather than nitrogen as carrier, because its higher diffusivity shifts the optimum to higher speed.

Chapter III

A Closer Look: Why Columns Are Thirty Metres Long

Martin and Synge's model treats the column as a sequence of discrete stages, each of which brings the two phases to equilibrium — theoretical plates, borrowed from distillation. A column of length LL with plate height HH has

N=LHN = \frac{L}{H}

plates, and a peak emerging from it has a width that grows as N\sqrt{N} while its retention grows as NN. So the sharpness of a peak relative to its position improves as the square root of the plate count, and the resolution between two peaks is

R=N4⋅α−1α⋅k1+k,R = \frac{\sqrt{N}}{4} \cdot \frac{\alpha - 1}{\alpha} \cdot \frac{k}{1+k},

where α\alpha is the ratio of the two components' affinities and kk their retention factor. Take the last factor as about 1, which it is for a well-chosen method, and ask what NN is needed for the minimum useful resolution, R=1R = 1.

Two components differing by 5% in affinity (α=1.05\alpha = 1.05):

N=4αα−1=4×1.050.05=84,N=7,100.\sqrt{N} = \frac{4\alpha}{\alpha - 1} = \frac{4 \times 1.05}{0.05} = 84, \qquad N = 7{,}100.

Two components differing by 1% (α=1.01\alpha = 1.01):

N=4×1.010.01=404,N=163,000.\sqrt{N} = \frac{4 \times 1.01}{0.01} = 404, \qquad N = 163{,}000.

That is the whole explanation of the shape of the apparatus. Resolving a one per cent difference requires of order 10510^{5} equilibrations, and since a packed column achieves a plate every few hundred micrometres, 10510^{5} plates means tens of metres. A packed column that long cannot be used, because forcing gas through the packing requires a pressure drop that nothing survives. Marcel Golay's open capillary solves exactly that: coat the stationary phase on the inside wall of a tube a quarter of a millimetre across and leave the middle empty, and 30 metres can be coiled into a palm-sized spiral with a modest pressure drop and 150,000 plates.

A falling line of theoretical plates needed against selectivity on log scales, marking 7,100 plates at 1.05 and 163,000 at 1.01.
Plates needed to separate two components, from the resolution equation with R=1R = 1. Five per cent apart takes 7,100; one per cent apart takes 163,000.Drawn for Field Atlas from the numbers above · Field Atlas original · Source

The square root is also the field's permanent frustration. To double the resolution, quadruple the plates: four times the length, four times the run time. The gain is real and it is expensive, which is why the other lever — changing α\alpha by choosing a different stationary phase — is pulled first. A tenfold improvement in selectivity costs nothing but a different column; a tenfold improvement in plate count costs a hundredfold in time.

That leads to the limit recorded above as an open problem. Peak capacity — the number of resolvable components — is roughly the run time divided by the average peak width, which for a good gas chromatogram is a few hundred. Blood plasma contains of order 10410^{4} small molecules. When a sample has more components than the run has slots, most peaks are mixtures, and the statistics of random arrival make it worse than a naive count suggests: filling 200 slots with 200 randomly placed components leaves well under half of them pure.

Chapter IV

What It Was Used For

The first great application was biological, and it used the least impressive apparatus in the field. Raphael Consden, Alfred Gordon and Martin spotted a protein hydrolysate on filter paper, let one solvent creep through it, dried it, and ran a second solvent at right angles. Every amino acid lands at its own coordinates, and the result is a map that can be read off by eye. For a sheet of paper and two jars of solvent, the method determined the amino acid composition of proteins, identified the intermediates of photosynthesis, and supplied Sanger with the means to identify the fragments in his insulin sequencing.

A strip of paper with a dark green spot at the left and a streak spreading to the right into green, blue-green and yellow bands.
Spinach pigments run out on paper: the green chlorophylls and yellow carotenoids pull apart, the separation Tsvet first saw in his column.Mattia Luigi Nappi, rotated by Peter coxhead · CC BY-SA 4.0 · Source

Then came the two instrumental versions, each opening a class of compounds the other could not reach. Gas chromatography, from 1952, is fast and extraordinarily resolving and requires the analyte to be volatile — excellent for hydrocarbons, flavours, pesticides and solvents, useless for a protein or most drugs. Csaba Horváth's high-performance liquid chromatography, from 1967, works for anything that dissolves, by packing the column with particles a few micrometres across and pushing solvent through at hundreds of atmospheres. The pharmaceutical industry runs on it: a drug's identity, its purity and its stability are all defined by what a specified liquid chromatographic method shows.

The carousel of a gas chromatograph's autosampler, loaded with small capped vials.
A gas chromatograph's autosampler, with a carousel of vials waiting to be injected one after another.Hey Paul, Sacramento · CC BY 2.0 · Source

James Jorgenson added the last variant in 1981 by replacing pressure with an electric field inside a capillary 75 micrometres across. The field drives the liquid with a flat velocity profile rather than the parabolic one that pressure produces, so the peaks do not smear, and the narrow bore carries away the heat that would otherwise wreck the separation. Hundreds of thousands of plates, from nanolitres of sample. Loaded with a polymer sieve and DNA fragments, arrays of such capillaries replaced slab gels in sequencing machines — which is how a separation technique ended up underneath genomics.

What chromatography cannot do is say what a peak is. It reports a time, and a time identifies a compound only by comparison with a standard that somebody has already obtained. Coupling the separation to an instrument that weighs each component as it emerges is mass spectrometry, and the combination is the most powerful analytical tool chemistry has.

Applications

Where it is used

  • Molecular biology↗ Biology · Genomics

    Reading a sequence by separating fragments

    Sanger's protein sequencing used two-dimensional paper chromatography to identify the fragments of partial hydrolysis, and his DNA sequencing method is a separation at its core: fragments differing by one nucleotide, resolved by length. The replacement of slab gels by capillary arrays is what made sequencing fast enough to finish a human genome, so a separation technique sits under the whole of genomics.

    › Sources (1)
    • Dovichi, N. J. & Zhang, J. (2000). How capillary electrophoresis sequenced the human genome. Angewandte Chemie International Edition 39: 4463–4468.
  • Pharmaceutical quality

    What a purity specification means

    A medicine's specification is largely chromatographic: the active substance must give a peak at the right retention time, of the right area, with no impurity peak above a threshold that is often 0.1% or less. Stability testing is the same analysis repeated over months. The method is the regulatory object, validated and filed, which is why changing a column supplier is a documented event.

    › Sources (1)
    • International Council for Harmonisation (2005). Validation of Analytical Procedures: Q2(R1).
  • Doping and forensics

    Finding a nanogram in a litre

    Anti-doping and forensic toxicology depend on separating a trace compound from a biological matrix containing thousands of others, then identifying it unambiguously. Chromatography supplies the separation and mass spectrometry the identification; neither alone would stand up in a hearing, which is why the coupling of the two is the legal standard of proof.

    › Sources (1)
    • Thevis, M. & Schänzer, W. (2007). Current role of LC-MS(/MS) in doping control. Analytical and Bioanalytical Chemistry 388: 1351–1358.

Open problems

Where the map runs out

Open

Separating a sample with more components than peaks

Open as of 2026; real samples routinely exceed the resolving power of the best available separations.

A good single chromatographic run resolves a few hundred components; coupling two separations with different selectivities raises it to a few thousand. Blood plasma contains on the order of 10410^{4} metabolites and proteoforms, crude oil more than 10510^{5} distinct compounds, and environmental samples an unknown number. Most peaks in such an analysis are therefore mixtures, and the statistics of random overlap make it worse: when the sample has as many components as the run has peak slots, the chance that any given peak is pure is small.

Why it is hard

Resolution improves only as the square root of column length or time, so a tenfold gain costs a hundredfold in both. Two-dimensional methods multiply the capacity only when the two separations are genuinely independent, which real stationary phases are not. And the detector cannot report what the separation failed to divide.

What resolving it unlocks

Untargeted metabolomics, environmental screening for unknown contaminants and the characterisation of biological drugs all depend on resolving components that have never been listed in advance.

› Sources (2)
  • Giddings, J. C. (1991). Unified Separation Science. Wiley.
  • Stoll, D. R. & Carr, P. W. (2017). Two-dimensional liquid chromatography: a state of the art tutorial. Analytical Chemistry 89: 519–531.

Further reading

  1. Ettre, L. S. & Zlatkis, A. (eds) (1979). 75 Years of Chromatography: A Historical Dialogue. Elsevier.

    Reminiscences by the people who built the methods, including why gas chromatography waited eleven years.

  2. Giddings, J. C. (1991). Unified Separation Science. Wiley.

    All separation methods as one subject, with the peak-capacity argument made properly.

  3. Snyder, L. R., Kirkland, J. J. & Dolan, J. W. (2010). Introduction to Modern Liquid Chromatography, 3rd edition. Wiley.

    The practitioner's reference; the chapters on resolution and gradient design are the useful ones.