Skip to content
Field Atlas

Atlas / Chemistry / The Analysis Thread

Field · Emerged 1916 – 2010

Surface and Imaging Analysis

How can the composition of the outermost few atomic layers be determined, when they are a billionth of the sample's mass?

4 chapters6 min read6 turning points1 open problem

Branched from
Spectroscopic Structure Determination + Catalysis
Branched into
Nanomaterials Chemistry
Figures
Irving Langmuir, Edward Teller, Stephen Brunauer, Paul Emmett, Clinton Davisson, Lester Germer, Kai Siegbahn, Raimond Castaing, Georges Slodzian

In brief

Catalysis, corrosion, adhesion, lubrication, semiconductor fabrication and the behaviour of a cell on an implant all happen in the top few atomic layers, and nothing in bulk analysis sees them. A monolayer on a square centimetre is about 101510^{15} atoms — a nanogram — against grams of material underneath, so any method that samples the bulk is swamped a billion to one.

The answer is to use probes that cannot escape from deep inside: an electron knocked out of an atom by an X-ray loses its energy within a nanometre or two of travel, so only electrons from the top few layers reach the detector with their original energy intact. Kai Siegbahn built that into a quantitative method in the 1960s, and the energy of the escaping electron reports not only which element it came from but what that element is bonded to — the chemical state, so that oxidised and metallic iron are distinguishable in the same spectrum. Before any of it, Langmuir's adsorption analysis and the Brunauer–Emmett–Teller extension gave the measurement everything else depends on: how much surface a powder actually has, which for a catalyst is typically hundreds of square metres per gram.

Key ideas

MonolayerEnters 1916 – 1918

One layer of atoms or molecules on a surface, about 101510^{15} per square centimetre. It is the natural unit of surface chemistry and about a nanogram of material, which is why surface analysis needs methods blind to the bulk.

Specific surface areaEnters 1938

Area per gram, measured by how much gas it takes to cover the surface with one layer. A finely divided catalyst reaches hundreds of square metres per gram, which is what makes a few grams of it industrially useful.

Inelastic mean free pathEnters 1954 – 1967

How far an electron travels in a solid before losing energy — one to three nanometres for the energies involved. It is the reason photoelectron spectroscopy is surface-specific: deeper electrons arrive with the wrong energy or not at all.

Chemical shift in core levelsEnters 1954 – 1967

The binding energy of a core electron shifts by a few electronvolts depending on the atom's oxidation state and neighbours, so a spectrum distinguishes metal from oxide, and sulfide from sulfate, as well as counting elements.

Depth profileEnters 1949 – 1980

Sputtering the surface away with an ion beam while analysing continuously, which converts a surface-specific method into a measurement of composition against depth — at the cost of destroying the sample and rearranging what remains.

Operando measurementEnters 1990 – 2010

Observing a material while it is working — a catalyst under reaction conditions, an electrode under potential — rather than before and after in a vacuum. It matters because the working surface is frequently not the surface that was characterised.

Chapter I

A Billionth of the Sample

Everything a solid does to its surroundings happens at its surface. A catalyst's activity, a metal's corrosion, whether glue sticks, whether a cell attaches to an implant, whether a transistor works — all are determined in the outermost few atomic layers, and all are invisible to the analysis of the material as a whole.

The numbers make the difficulty plain. A square centimetre of surface carries about 101510^{15} atoms, which is roughly a nanogram. A gram of the same material contains 102210^{22} atoms. Any technique that samples the bulk sees the surface diluted by a factor of 10710^{7} or more, which is to say it does not see it at all.

Irving Langmuir made the first quantitative progress without any surface-specific instrument, by treating the surface as a set of chemical sites. Adsorption, he argued in 1916, is an equilibrium: gas molecules land on a fixed number of identical sites, each holding one molecule, and desorb again. The resulting relation between pressure and coverage rises and then saturates, and the saturation level counts the sites. A surface acquired a measurable capacity.

Photograph of Irving Langmuir wearing round glasses and a suit.
Irving Langmuir, whose 1916 isotherm treated a surface as a set of sites that gas molecules fill and leave.Unknown photographer · Public domain · Source

Stephen Brunauer, Paul Emmett and Edward Teller extended it in 1938 to the case that actually occurs — molecules continuing to pile up in further layers once the first is full — and their equation, fitted over a modest range of pressures, extracts the amount of gas corresponding to exactly one layer. That is the measurement on which the whole of heterogeneous catalysis rests, and it is still what a catalyst's specification quotes.

Chapter II

Probes That Cannot Escape From Deep

The breakthrough in surface specificity came from choosing a signal that is absorbed by the material itself. An X-ray penetrates micrometres into a solid and ejects electrons all the way down; but an electron travelling through a solid loses energy within one to three nanometres. So electrons arriving at a detector with their full original energy must have come from the top few atomic layers. Depth sensitivity is obtained not by focusing but by attenuation.

Kai Siegbahn built spectrometers able to measure those energies to a fraction of an electronvolt, and found more than he needed. The binding energies identify the elements, as expected. The small shifts in those energies — typically one to six electronvolts — identify the chemical state, because an atom that has given up electron density to a neighbour holds its remaining core electrons more tightly. Metallic iron and iron in an oxide give separate peaks a few electronvolts apart, so a single spectrum reports both what is there and what it is bonded to. He called it electron spectroscopy for chemical analysis, and the shifts are the reason it is a chemical technique rather than an elemental one.

Two companions complete the toolkit. Low-energy electron diffraction, available once ultra-high vacuum could keep a surface clean for hours rather than seconds, showed that a clean crystal surface is not the bulk structure cut in half — the top layers rearrange into periodicities of their own, and silicon's reconstruction took twenty years to solve. And secondary ion mass spectrometry sputters the surface away with an ion beam while weighing what comes off, which destroys the sample and in exchange gives composition against depth at a few nanometres' resolution, the measurement semiconductor manufacturing depends on.

Bright spots in a square arrangement on a dark fluorescent screen, around a central shadow.
A low-energy electron diffraction pattern from a clean platinum–rhodium crystal face. The spots map the arrangement of the outermost atoms.Mkosterv · CC0 · Source

Chapter III

A Closer Look: How Much Surface Is in a Gram

Before any of those instruments, the measurement everything else rests on is the crudest: how much surface there is. A commercial catalyst support is quoted at 200 square metres per gram. Both halves of that figure repay checking, because the number sounds impossible and follows from simple geometry.

From area to particle size. For spheres of diameter dd and density ρ\rho, the area per unit mass is

Am=πd2ρ⋅π6d3=6ρd.\frac{A}{m} = \frac{\pi d^{2}}{\rho \cdot \tfrac{\pi}{6}d^{3}} = \frac{6}{\rho d}.

Setting A/m=200A/m = 200 m²/g =2×105= 2\times10^{5} m²/kg and ρ=2000\rho = 2000 kg/m³:

d=6ρ(A/m)=6(2000)(2×105)=1.5×10−8 m=15 nm.d = \frac{6}{\rho (A/m)} = \frac{6}{(2000)(2\times10^{5})} = 1.5\times10^{-8}\ \mathrm{m} = 15\ \mathrm{nm}.

So 200 m²/g corresponds to particles about 15 nanometres across — or to a porous solid whose internal pores are of that scale, which is what a zeolite or a silica gel is. Two hundred square metres is nearly the area of a tennis court, inside one gram.

How much of it is actually surface. For a 15 nm particle the fraction of atoms in the outermost layer is roughly 6a/d6a/d, where aa is an atomic diameter of about 0.25 nm:

6×0.2515=10%.\frac{6 \times 0.25}{15} = 10\%.

A tenth of the atoms are available to do chemistry, which for an expensive metal is the difference between a viable process and an uneconomic one. Dispersing platinum as 2 nm particles raises that fraction to about three quarters, and this is why catalytic converters contain grams rather than kilograms of the metal.

A falling curve of the fraction of atoms at the surface against particle diameter, three quarters at 2 nm and 10 per cent at 15 nm.
The fraction of atoms in the outermost layer, roughly 6a/d6a/d. At 15 nm, a 200 m²/g support, it is a tenth; platinum at 2 nm puts three quarters of its atoms at the surface.Drawn for Field Atlas from the numbers above · Field Atlas original · Source

What the instrument measures. A nitrogen molecule occupies 0.162 nm² when packed in a monolayer, so covering 200 m² requires

2000.162×10−18=1.23×1021 molecules=2.05 mmol,\frac{200}{0.162\times10^{-18}} = 1.23\times10^{21} \text{ molecules} = 2.05\ \mathrm{mmol},

which at standard temperature and pressure is

2.05×10−3×22,414=46 cm3.2.05\times10^{-3} \times 22{,}414 = 46\ \mathrm{cm^{3}}.

Forty-six cubic centimetres of nitrogen gas, measured by the pressure drop in a known volume as a cooled sample takes it up. That is the entire BET experiment, and it is why the area of a powder can be stated to a few per cent from a measurement of gas pressure.

The limits. The method assumes that all the gas taken up is on an accessible surface and that the molecule's footprint is known. For pores only slightly wider than the molecule, neither holds — gas condenses in them by a different mechanism, and the area reported is an artefact of applying the equation outside its range. Areas quoted for microporous materials above about 3,000 m²/g should be read as a characterisation parameter rather than as a geometric area, since they begin to exceed what the atoms present could physically expose.

Chapter IV

The Gap That Remains

All of that was built in ultra-high vacuum on single crystals, and its subject matter mostly operates at atmospheric pressure on powders. The difference is thirteen orders of magnitude in pressure and a different material, and it is not a detail: surfaces reconstruct when covered by adsorbates, alloys segregate so that one component enriches at the surface, oxides reduce, and particles sinter together while working.

Ambient-pressure photoelectron spectroscopy, which uses differential pumping and a synchrotron's brightness to keep a usable signal with gas present, and X-ray absorption measurements taken during reaction, have narrowed the gap and made its importance obvious. Catalysts routinely turn out to be something other than what was loaded into the reactor, and the active site is often a minority feature — a step edge, a defect, an interface — that constitutes a per cent or two of the surface and does most of the chemistry.

That is the open problem above, and it is the same problem catalysis records from the other side: the reason catalyst development still proceeds by screening thousands of formulations is that the thing being designed cannot yet be watched while it works.

Applications

Where it is used

  • Semiconductor manufacture↗ Physics · Solid-State Physics

    Composition measured to the atomic layer

    A transistor's behaviour depends on dopant concentrations in layers nanometres thick, on the composition of gate dielectrics a few atoms across, and on the absence of contaminants at parts per billion of a monolayer. Secondary ion mass spectrometry supplies the depth profiles and photoelectron spectroscopy the chemical states, as routine process control rather than research.

    › Sources (1)
    • Vickerman, J. C. & Gilmore, I. S. (eds) (2009). Surface Analysis: The Principal Techniques, 2nd edition. Wiley.
  • Corrosion and coatings

    Why a passive film is only nanometres thick

    The oxide that protects stainless steel or aluminium is two to five nanometres thick, which no bulk method can examine and photoelectron spectroscopy measures directly — its thickness, its composition and the proportion of chromium enriched in it. Testing whether a treatment improves corrosion resistance is therefore a surface measurement, and the failure of a coating is diagnosed the same way.

    › Sources (1)
    • Olefjord, I. & Wegrelius, L. (1990). Surface analysis of passive state. Corrosion Science 31: 89–98.
  • Biomaterials↗ Biology · Cell Biology

    What a cell actually meets

    A cell approaching an implant encounters neither titanium nor polymer but the layer of protein that adsorbed from the surrounding fluid within seconds, on an oxide a few nanometres thick. Whether the implant integrates or is walled off depends on that layer's composition and conformation, which is a surface-analytical question, and it is why implant surfaces are specified by their chemistry and topography rather than by the bulk material.

    › Sources (1)
    • Castner, D. G. & Ratner, B. D. (2002). Biomedical surface science: foundations to frontiers. Surface Science 500: 28–60.

Open problems

Where the map runs out

Open

What the surface of a working catalyst is

Open as of 2026; the gap between characterised and working surfaces is narrowed, not closed.

Surface science's quantitative results come from single crystals in ultra-high vacuum; industrial catalysis uses powders at atmospheres or more, often in liquids. Both the pressure gap and the materials gap matter: surfaces reconstruct under adsorbates, metals segregate, oxides reduce, particles sinter and the active site may be a minority feature such as a step or a defect that constitutes a per cent of the surface and does most of the work.

Why it is hard

Techniques that are surface-specific generally require vacuum, because the probe is an electron and electrons do not travel far in gas. Methods that tolerate pressure usually average over the whole sample, so the minority active site is invisible. And the surface changes while being measured, including in response to the probe.

What resolving it unlocks

Catalyst design currently proceeds by screening because the thing being designed cannot be observed in operation. Identifying active sites under working conditions is the prerequisite for designing them deliberately, which is the open problem of catalysis seen from the instrumental side.

› Sources (2)
  • Somorjai, G. A. & Park, J. Y. (2008). Molecular surface chemistry by metal single crystals and nanoparticles from vacuum to high pressure. Chemical Society Reviews 37: 2155–2162.
  • Tao, F. & Salmeron, M. (2011). In situ studies of chemistry and structure of materials in reactive environments. Science 331: 171–174.

Further reading

  1. Somorjai, G. A. & Li, Y. (2010). Introduction to Surface Chemistry and Catalysis, 2nd edition. Wiley.

    The standard text linking surface structure to catalytic behaviour, with the vacuum-to-pressure problem discussed throughout.

  2. Vickerman, J. C. & Gilmore, I. S. (eds) (2009). Surface Analysis: The Principal Techniques, 2nd edition. Wiley.

    Each technique's physics, depth sensitivity and limitations, written by practitioners.

  3. Duke, P. J. (2000). Synchrotron Radiation: Production and Properties. Oxford University Press.

    Where the photons for ambient-pressure surface spectroscopy come from, and why a synchrotron is needed.